16 | Landscape & Turf Product Catalog NETAFIM USA TECHLINE® CV TECHLINE CALCULATOR DOWNLOAD FROM THE APP STORE OR GOOGLE PLAY FLOW PER 100 FEET 12” 18” 24” 0.26 EMITTER 0.42 EMITTER 0.92 EMITTER EMITTER SPACING GPH GPM GPH GPM GPH GPM GPH GPM 26.4 0.44 42.3 0.71 60.8 1.01 92.5 1.54 17.6 0.29 28.2 0.47 40.5 0.68 61.6 1.03 - - - - 30.4 0.51 46.2 0.77 0.61 EMITTER INLET PRESSURE MAXIMUM LENGTH OF A SINGLE LATERAL (FEET) 20 psi 25 psi 35 psi 45 psi 55 psi 60 psi EMITTER SPACING 12” 18“ 24” EMITTER FLOW (GPH) 0.26 0.42 0.61 0.92 0.26 0.42 0.61 0.92 0.61 0.92 331 242 190 144 468 344 270 204 342 260 413 302 238 180 584 429 338 257 430 326 518 380 299 227 737 540 426 323 542 412 594 436 343 260 845 620 489 371 622 472 655 480 378 287 932 684 539 410 686 522 681 500 393 298 969 713 561 426 716 544 SPECIFYING MODEL NUMBER TLCV4-1210 3 1 A SAMPLE MODEL NUMBER Techline CV Dripline = TLCV A EMITTER SPACING 2 12” 18” 24” = 12 = 18 = 24 COIL LENGTH 3 100’ 250’ 500‘ 1,000’ = 01 = 025 = 05 = 10 EMITTER FLOW RATE 0.26 GPH 0.42 GPH 0.61 GPH 0.92 GPH = 26 = 4 = 6 = 9 1 2 1.0 0.8 0.6 0.4 0.2 0 10 20 30 40 50 58 PRESSURE (psi) FLOW RATE (GPH) 0.61 GPH 0.42 GPH 0.26 GPH 0.92 GPH Techline CV emitters open at 14.5 psi and close at 2 psi. FLOW RATE VS. PRESSURE FLOW CODE EMITTER SPACING COIL LENGTH MODEL NUMBER TLCVX-1201 TLCVX-12025 TLCVX-1210 TLCVX-1801 TLCVX-18025 TLCVX-1810 TLCVX-2401 TLCVX-24025 TLCVX-2410 12” 18” 24“ 100’ 250’ 1,000’ 100’ 250’ 1,000’ 100’ 250’ 1,000‘ 26 4 6 9 FLOW RATE 0.26 0.42 0.61 0.92 ORDERING INFORMATION BLANK TUBING 100’ 250’ 500‘ 1,000’ TLCV001 TLCV0025 TLCV005 TLCV010 COIL LENGTH MODEL NUMBER * Substitute X in the Model Number with Flow Code * See General Guideline on Page 7.