NETAFIM USA Landscape & Turf Product Catalog | 15 Large inlet filtration area (entire base of emitter) Diaphragm Emitter outlet (top of emitter) Physical root barrier prevents roots from penetrating the emitter Unique patented TurboNet technology wide flow path allows more control of water flow and less chance for clogging Check valve (CV) mechanism Anti-vacuum (AS) mechanism prevents suction of dirt into the dripline TECHLINE® CV 17mm DRIPLINE Maximum Uniformity in Subsurface and On-surface Including Slopes. APPLICATIONS • Subsurface or on-surface turf, shrubs, trees and flowers • Sports turf, tennis courts, golf courses • Slopes • Longer lateral runs • Curved, angular or narrow planting areas • High traffic/high liability areas • Areas subject to vandalism • High wind areas • At-grade windows • Green walls, green roofs • Raised planters SPECIFICATIONS • Broadest choice of emitter flow rates: 0.26, 0.42, 0.61 and 0.92 GPH • Emitter spacings: 12”, 18“ and 24” (24” spacing available for 0.61 and 0.92 GPH only) • Pressure compensation range:1 4.5 to 58 psi • Bending radius: 7” • Maximum recommended system pressure: 58 psi • Minimum pressure required: 14.5 psi • Tubing diameter: 0.66“ OD; 0.56” ID; 0.050” wall • Coil lengths: 100’, 250’, 500‘, 1,000’ • Recommended minimum filtration: 120 mesh • Diaphragm made of silicon • ISO 9261 Standard Compliance FEATURES & BENEFITS 2 psi CHECK VALVE IN EACH EMITTER All emitters turn on and off at the same time, maximizing balance of application. Holds back up to 4.6’ of water (elevation change). No low emitter drainage, great on slopes. Delivers more precise watering. UNIQUE PATENTED EMITTER DESIGN WITH PHYSICAL ROOT BARRIER Offset flow path, extra large bath area and raised outlet prevent root intrusion without chemical reliance. PRESSURE COMPENSATING Precise and equal amounts of water are delivered over a broad pressure range. CONTINUOUS SELF-FLUSHING EMITTER DESIGN Flushes debris as it is detected, throughout operation, not just at the beginning or end of a cycle, ensuring uninterrupted emitter operation. EMITTER WITH ANTI-SIPHON FEATURE Prevents ingestion of debris into tubing caused by vacuum. SELF-CONTAINED, ONE-PIECE DRIPLINE CONSTRUCTION Assures reliable, easy installation. FLEXIBLE UV RESISTANT TUBING Adapts to any planting area shape - tubing curves at a 7” radius. For on-surface installations withstands heat and direct sun. MAKES INSTALLATION QUICKER Does not require automatic flush valve for on-surface or subsurface installations. Use manual flush valves at exhaust headers. QUALIFIES FOR USE ON LEED PROJECTS Exploded View of Techline CV Emitter
RkJQdWJsaXNoZXIy NDU2MA==